Your position: Home / Electronic Components

New version frequency meter High frequency 10MHz-2.4GHz / Low frequency 0-50MHz with counting function

TOP41067
New version frequency meter High frequency 10MHz-2.4GHz / Low frequency 0-50MHz with counting function
Quantity:
-
+
(1000 available)
Shipping Cost:
to
Estimated Delivery Time:
Please select the country you want to ship from
Please select the information you wantX
  • Description
  • Reviews

I. Overview:
HZ310 is a small frequency meter that can measure low and high frequency signals.
This module is simple to use, and can be operated by pressing keys to select different test methods.

Product application:
● Measuring pulse frequency;
● Measuring radio frequency;

 

Third, the technical parameter table:
Item Item Parameter Unit Remark

 

Third, the technical parameter table:
The number of the project: the parameters of the unit, the unit, the unit, and the unit
1. Measure the low-frequency range: 1Hz ~ 50MHz
2 Measure the low-frequency voltage range +/- 0.7V ~ 15V
3 Measuring low-frequency resolution 1 Hz
4 Measure the high frequency range 10MHz ~ 2.4GHz
5 Measure high-frequency voltage range +/- 100mV ~ +/- 5V
6. Measurement of high-frequency resolution 1KHZ Hz
7. Working voltage: 7 ~ 12. VDC
8. Working current: <50. MA
9 Working temperature: -40 ℃ ~ 65 ℃
10. Storage temperature: -40 ℃ ~ 65 ℃
11 Dimensions: 57 * 50 * 20 mm length X width X height

Note: The low-frequency signal is not an AC signal, and a capacitor of about 1 OuF is connected in series at the input signal end.
The low-frequency signal is DC-coupled. For AC-coupling, please measure the capacitance in series.

Fourth, the interface description and related operations
P1 interface (power)
VDD: power positive (7 ~ 12V)
GND: power negative

P3 interface (output signal)
50M: measure low frequency input signal.
GND: negative power supply.
GX: measure high frequency input signal.
GND: negative power supply.

 

 Fourth, the key description

FUN: select (high / low frequency) measurement method
MODE: Select display unit / counter to clear.
 
 
4.1 Low frequency measurement
Interface display font:
The first line "1.FX = 50MHZ"
The second line "00000000Hz"
Key operation:
MODE: Select the display unit.
 
4.2 High-frequency measurement
Interface display font:
The first line "2.RF = 2.4GHz"
The second line "0000.000MHz"
Key operation:
 
 
4.3.Accumulation counter (measures up to 100KHz)
Interface display font:
First line "3.FX = Counter"
The second line "00000000n"
Key operation:
MODE: The counter is cleared.

Low frequency measurement

High frequency measurement

 

 

Accumulation counter