Module parameters
1. Supply voltage: 9V to 24V
2. Signal input voltage range: 4 ~ 24V
3.signalInput frequency range: 0Hz ~ 100Hz
4.signalInput RC range: 500 ~ 2500us (microseconds)
5. Output voltage: 0.00V ~ 5.00V / 0.00V ~ 10.00V
6. Input method: J1 pad on the circuit board: open by default, not used.
7. Output method: J2 pad on the circuit board: open circuit (output 0.00V to 5.00V); short circuit (output 0.00V to 10.00V), the default is open circuit.
8. Application: remote data acquisition and control equipment;
9. Size: (length) 26mm * (width) 23mm * (height) 10mm
10. Module interface:
12V: positive power connector (9V to 24V).
G: Power ground interface.
IN: Signal input positive connector.
G: signal input negative connector.
OUT: Signal output interface (0.00V to 5.00V / 0.00V to 10.00V).
G: Power ground interface.
Note: When outputting 0.00V to 10.00V, the power supply voltage must be 15V.
RC signal500 ~ 2500us (microseconds) turn (0.00V to 5.00V) or (0.00V to 10.00V)